wabco ebs epb Terminal 15 / Supply line short-circuit UBatt
wabco ebs epb Terminal 15 / Supply line short-circuit UBatt
How can i make this fault
Terminal 15 / Supply line short-circuit UBatt
Code 13.5
Terminal 15 / Supply line short-circuit UBatt
--------------------------------------------------------------------------------
- Check the "terminal 15" power supply line (steady positive voltage?)
- Check the ignition switch (defective?)
- Is the ignition switch information correct for the PLD system ?
- Replace the EBS control unit
Terminal 15 / Supply line short-circuit UBatt
Code 13.5
Terminal 15 / Supply line short-circuit UBatt
--------------------------------------------------------------------------------
- Check the "terminal 15" power supply line (steady positive voltage?)
- Check the ignition switch (defective?)
- Is the ignition switch information correct for the PLD system ?
- Replace the EBS control unit
- acckiy
- Сообщения: 2166
- Зарегистрирован: Вс авг 24, 2008 9:34 pm
- Откуда: Россия. Санкт-Петербург
- Контактная информация:
Re: wabco ebs epb Terminal 15 / Supply line short-circuit UB
Was it checked?enko писал(а):- Is the ignition switch information correct for the PLD system ?
Is it correctly switchable?enko писал(а):- Check the "terminal 15" power supply line (steady positive voltage?)
Re: wabco ebs epb Terminal 15 / Supply line short-circuit UB
Ignition switch off.
Check terminal 15 EBS control unit short Ubat.
Check terminal 15 EBS control unit short Ubat.
- acckiy
- Сообщения: 2166
- Зарегистрирован: Вс авг 24, 2008 9:34 pm
- Откуда: Россия. Санкт-Петербург
- Контактная информация:
Re: wabco ebs epb Terminal 15 / Supply line short-circuit UB
Also the BS/EPB ECU shouldn't receive an messages via CAN from PLD ECU like a "ignition is on" when it is really off-stage.den_2001 писал(а):Ignition switch off